Rhino Environmental Services, Inc.

Reviving the Concept of Customer Service

Treatment Sampling Requirements

Serving New Mexico & El Paso Since 1989

 

In general, representative samples (EPA SW 846) should be analyzed according to the following:          

 

             a.  Gasoline Impacted Soil or Water - Mod. 8015 (GRO), TCLP Benzene and Ignitability

 

             b.  Leaded Gasoline Impacted Soil or Water - Mod. 8015 (GRO), TCLP Benzene, Ignitability and  TCLP (or                   Total) Pb

 

             c.  Diesel Impacted Soil or Water - Mod. 8015 (DRO) and Ignitability

 

             d.  Waste Oil Impacted Soil or Water - Mod. 8015 (DRO), TCLP (Cd, As, Cr, Pb), TCLP Vol/Semi-Vols and 

                  Ignitability

 

             e.  Hydraulic Fluid / Transformer Oil- Mod. 8015 (DRO), TCLP metals (RCRA 8), Ignitability and PCBs (or                    MSDS demonstrating no PCBs)

 

Note: For those wastes generated in Texas, TX 1005/1006 will satisfy testing requirements for TPH.

 

For exemptions and more information, please call 1-800-762-0241

 

When requesting treatment/disposal services for petroleum contaminated water and/or soil, the following information is required:

 

             a.  Completed and Signed Waste Profile Sheet

             b.  Copies of analytical data, inclusive of quality control data and chain of custody.